{"title":"Commercial Hybrid Inverters","description":null,"products":[{"product_id":"sol-ark-30k-3p-208v-commercial-hybrid-inverter","title":"Sol-Ark 30K-3P-208V Commercial Hybrid Inverter","description":"\u003cp\u003eA three-phase hybrid inverter for light commercial sites. Native 120\/208V three-phase output removes the need for bulky step-down transformers in most small commercial buildings. The Sol-Ark 30K cuts demand charges through solar optimization and peak shaving, adds storage to existing grid-tied PV through AC coupling, and DC-couples new arrays efficiently with four MPPT channels. Scale from 30kW to 300kW with up to 10 units.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative 120\/208V 3-phase:\u003c\/strong\u003e no transformer needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 MPPTs,\u003c\/strong\u003e up to 39kW PV; 30kW AC coupling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e45kVA surge;\u003c\/strong\u003e 200A grid relay with 15ms transfer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 10 in parallel\u003c\/strong\u003e (300kW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePairs with Sol-Ark L3 Series\u003c\/strong\u003e high-voltage batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWi-Fi\/LAN\u003c\/strong\u003e monitoring via MySolArk; 10-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePV input\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV (STC)\u003c\/td\u003e\n\u003ctd\u003e39,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT range \/ start-up\u003c\/td\u003e\n\u003ctd\u003e150–500V \/ 180V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax input voltage\u003c\/td\u003e\n\u003ctd\u003e550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPTs × strings\u003c\/td\u003e\n\u003ctd\u003e4 × 2; 36A per MPPT (55A Isc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC-coupled input\u003c\/td\u003e\n\u003ctd\u003e30,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAC output\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120\/208V 3-phase; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous power\u003c\/td\u003e\n\u003ctd\u003e30,000W (83.4A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak (10 s, off-grid)\u003c\/td\u003e\n\u003ctd\u003e45,000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid passthrough\u003c\/td\u003e\n\u003ctd\u003e200A (10 min) \/ 180A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e15ms (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e96.5% CEC \/ 97.5% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBattery \u0026amp; general\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eHigh-voltage lithium-ion, ≥300V nominal (160–500V), 2 inputs, 100A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS communication\u003c\/td\u003e\n\u003ctd\u003eCAN (active BMS required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e35.2 × 20.8 × 11.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e176 lbs (80 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ NEMA 3R; -40 to 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 1741 SB, UL 1741 CRD-PCS, UL 1699B, CSA C22.2 107.1-16, IEEE 1547-2018\/1547.1-2020 (SRD 2.0); CEC, SGIP, CSIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Sol-Ark","offers":[{"title":"Default Title","offer_id":44582550503502,"sku":"900-00017","price":10998.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/9064\/9678\/files\/sol-ark-30k-3p-208v-commercial-hybrid-inverter-8105209.jpg?v=1792433409"},{"product_id":"sol-ark-60k-3p-480v-commercial-hybrid-inverter","title":"Sol-Ark 60K-3P-480V Commercial Hybrid Inverter","description":"\u003cp\u003eSol-Ark's 60kW commercial hybrid inverter for large commercial and industrial sites. Native 277\/480V Wye or 480V Delta output means no external transformer. It accepts up to 78kW of PV at up to 1,000V across four MPPTs, AC-couples existing arrays, and scales from 60kW to 600kW with up to 10 units. Use it to cut demand charges, back up operations and join grid programs.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative 277\/480V Wye or 480V Delta\u003c\/strong\u003e 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 MPPTs,\u003c\/strong\u003e 78kW PV, 1,000V max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90kVA surge;\u003c\/strong\u003e 200A grid relay, 15ms transfer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 10 in parallel\u003c\/strong\u003e (600kW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePairs with L3 Series\u003c\/strong\u003e HV batteries (40kWh to 9.6MWh)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e10-year warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePV input\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV (STC)\u003c\/td\u003e\n\u003ctd\u003e78,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT range \/ start-up\u003c\/td\u003e\n\u003ctd\u003e150–850V \/ 180V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax input voltage\u003c\/td\u003e\n\u003ctd\u003e1,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPTs × strings\u003c\/td\u003e\n\u003ctd\u003e4 × 2; 36A per MPPT (55A Isc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC-coupled input\u003c\/td\u003e\n\u003ctd\u003e60,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAC output\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e277\/480V 4-wire Wye or 480V 3-wire Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous power\u003c\/td\u003e\n\u003ctd\u003e60,000W (72.3A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak (10 s, off-grid)\u003c\/td\u003e\n\u003ctd\u003e90,000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid passthrough\u003c\/td\u003e\n\u003ctd\u003e200A (10 min) \/ 180A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd\u003e15ms (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e96.5% CEC \/ 97.5% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBattery \u0026amp; general\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eHigh-voltage lithium-ion, ≥600V nominal (160–700V), 2 inputs, 100A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS communication\u003c\/td\u003e\n\u003ctd\u003eCAN (active BMS required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e35.2 × 20.8 × 11.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e176 lbs (80 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ NEMA 3R; -40 to 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 1741 SB, UL 1741 CRD-PCS, UL 1699B, CSA C22.2 107.1-16, IEEE 1547-2018\/1547.1-2020 (SRD 2.0); CEC, SGIP, CSIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eNot for corner-grounded delta, high-leg delta or 240V delta systems. The L3-HVR power transformer is required when pairing with the L3-HVR outdoor battery.\u003c\/p\u003e","brand":"Sol-Ark","offers":[{"title":"Default Title","offer_id":44582550569038,"sku":"900-00025","price":13185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/9064\/9678\/files\/sol-ark-60k-3p-480v-commercial-hybrid-inverter-7155213.jpg?v=1792433408"}],"url":"https:\/\/skysolarusa.com\/collections\/commercial-hybrid-inverters.oembed","provider":"Sky Solar USA","version":"1.0","type":"link"}