{"product_id":"kohler-26rcal-200sels-26-kw-standby-generator-rxt-200-amp-se-n3r-w-load-man","title":"KOHLER 26RCAL-200SELS 26 kW Standby Generator — RXT 200 Amp, SE, N3R, w\/LOAD Man","description":"\u003cp\u003eThe KOHLER 26RCAL provides permanently installed standby power for your home. Connected to a suitable natural gas or LP fuel supply and a compatible automatic transfer switch, it starts when utility power fails and supports the circuits selected for backup.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic backup:\u003c\/strong\u003e Designed to work with a compatible automatic transfer switch for unattended outage response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel flexibility:\u003c\/strong\u003e Natural gas or LP operation using a permanent fuel connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine design:\u003c\/strong\u003e Air-cooled KOHLER engine in a protective outdoor enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator control:\u003c\/strong\u003e RDC2 controller coordinates generator operation and compatible RXT transfer-switch functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService access:\u003c\/strong\u003e Oil drain extension with shutoff valve simplifies routine oil service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor enclosure:\u003c\/strong\u003e Powder-coated aluminum enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStarting performance:\u003c\/strong\u003e Designed to handle motor-starting loads such as air-conditioning equipment, subject to proper system sizing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eKOHLER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e26RCAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower class\u003c\/th\u003e\n\u003ctd\u003e26 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas \/ LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eAir-Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated output — natural gas\u003c\/th\u003e\n\u003ctd\u003e24 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated output — LP\u003c\/th\u003e\n\u003ctd\u003e26 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eController\u003c\/th\u003e\n\u003ctd\u003eRDC2 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine displacement\u003c\/th\u003e\n\u003ctd\u003e999 cm³ (61 cu. in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine speed\u003c\/th\u003e\n\u003ctd\u003e3600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical configuration\u003c\/th\u003e\n\u003ctd\u003e26RCAL, RXT 200 Amp, SE, NEMA 3R, with load management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLine circuit breaker\u003c\/th\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGenerator dimensions\u003c\/th\u003e\n\u003ctd\u003e1193 mm x 660 mm x 820 mm (47 in. x 26.0 in. x 32.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eManufacturer SKU:\u003c\/strong\u003e 26RCAL-200SELS\u003c\/p\u003e\u003ch3\u003eIncluded equipment\u003c\/h3\u003e\u003cp\u003eGenerator and RXT 200-amp service-entrance-rated automatic transfer switch with load management in a NEMA 3R enclosure.\u003c\/p\u003e\u003ch3\u003eInstallation and sizing\u003c\/h3\u003e\u003cp\u003eMatch voltage, phase, fuel supply, and connected loads to the selected configuration. Output depends on fuel and operating conditions. Installation, fuel-system work, and transfer-switch connections require a qualified installer.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.kohlerhomeenergy.rehlko.com\/products\/home-generators\/26rcal\" target=\"_blank\" rel=\"noopener\"\u003eView KOHLER model information and manuals\u003c\/a\u003e\u003c\/p\u003e","brand":"KOHLER","offers":[{"title":"Default Title","offer_id":44582242287694,"sku":"26RCAL-200SELS","price":8266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/9064\/9678\/files\/kohler-gm101737-s1-cas-replacement-enclosure-for-1420rca-generators-cashmere-1902535.png?v=1792431846","url":"https:\/\/skysolarusa.com\/products\/kohler-26rcal-200sels-26-kw-standby-generator-rxt-200-amp-se-n3r-w-load-man","provider":"Sky Solar USA","version":"1.0","type":"link"}